What procedures will have to go to get AS2047 approved?


You must be curious what characteristics AS2047 certificated windows and doors have to differentiate from other non-AS2047 certificated windows? Now let's explore and reveal the truth: 


AS2047 incorporates the testing procedures outlined in AS4420 parts 0 through to 6 – test methods for doors and windows, establishing these as the minimum requirment for conformace to AS2047. It is the mandatory minimum specification for windows and doors used in Australia it includes compliance to the Glass Standard AS 1288. The following performance tests are undertaken to verify product performance claims.


1) Methods of test  –AS 4420.1 Windows –Method 1: Test sample, preparation for tests, and test sequence


2) Deflection test – AS4420.2: This standard addresses the deflection/span ratio of the window test sample under wind load. The deflection ratio is measured in both positive and negative load at the desired design pressure for the window under test.


3) Operating force test – AS4420.3: This standard addresses the operating force for sliding sashes of the window test sample. The force to open and close a window either horizontally or vertically is measured and recorded in both directions.

4) Air infiltration test – AS4420.4: This standard addresses the resistance of the window test sample to air infiltration. Air flow is measured and recorded at low pressures indicating the amount of air leakage emanating from the product under test.


5) Water Penetration test – AS4420.5: This standard addresses the resistance of the window test sample to water penetration (under static wind load). Water is sprayed onto the product under test at a controlled rate and static pressure is applied for fifteen minutes at the desired design capability of the product.


6) Ultimate strength test – AS4420.5: This standard addresses the ultimate load capacity of the window test sample. A pressure is applied to a product that represents a peak load at which the product needs not fail after 10 seconds in both positive and negative


Only after products have passed by those above tests and also factory inspection, then they will get the AS2047 certification


AMJ Building is a AS2047 certificated manufacturer for aluminium windows and doors with production exeperience for over 10 years, our products ranging from Louvres, Bifolds, Sliding Doors, Sliding Windows, Awning, Casements, Glass wall, Curtain wall, and Balustrading & Glass to suit all energy requirements & security needs, any questions about aluminium & glass products, pls feel free contact us for expert advise and free quote.


   You can check any suppliers who have been approved by SAI Global and whether their certificatte is valid in this website:  https://register.saiglobal.com/default.aspx






CONTACT INFORMATION:


Sales Manager: Jacqueline Jin

Tel:+86 181 2608 7332

WhatsApp/WeChat:+86 136 2868 9546

Email: amjone@aubuilding.com

Add: NO. 46, Donghuan Road, Qingxi Town, Dongguan City, Guangdong Province, China.

文章推荐

   

    Call Us:+86-181-2608-7332

    emall:amjone@aubuilding.com

    Fax:86 0755-28283230

    Address:NO. 46,Donghuan Road, Qingxi Town, Dongguan City, Guangdong province, China.

Copyright Shenzhen AMJ Technology CO., Ltd

版权所有:深圳市澳美居科技有限公司

备案号:粤ICP备19044334号

     PRODUCTS

     PROJECTS

     ABOUT  US

     CONTACT  US

添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了